Skip to content
PrestiVac

Static dissipating throughout

ESD Static Free Vacuum Cleaners

Built with static dissipating components throughout — housings, filters, hoses and tools — so charge cannot accumulate where it matters.

PrestiVac stainless steel ESD static free industrial vacuum cleaner

What defines this line

  • Static dissipating housings, filters, hoses and tools
  • Continuous grounded and bonded recovery path
  • Suited to both ignition prevention and component protection
  • Solid stainless steel construction

Certification & documentation

Certified models are covered by CSA Certificate 70122393, assessed against UL 1203 (5th Edition). Scope differs by line: the EX1 HEPA line carries Class I, Gp. D; Class II, Gps. E, F and G; Temp. Code T3C. The EV EX HEPA line carries Class II, Div. 2, Gps. F and G only. Each model page states which scope applies to that unit.

Area classification is determined by your own engineering assessment. We match equipment to the classification you provide — see how Classes, Divisions and Groups work.

How to choose within this line

  1. 01

    Decide which risk you are managing

    Preventing a discharge from igniting combustible dust and protecting sensitive components from electrostatic damage are different requirements. Many facilities need both — say so and we will specify for both.

  2. 02

    The whole chain must dissipate

    Housings, filters, hoses and tools all form part of the path to ground. A conductive unit at the end of an ordinary plastic hose has a gap in the middle of its protection.

  3. 03

    Confirm the area classification

    Where the dust is combustible, classification determines which power units and construction are acceptable. Your engineer assigns it; we match equipment to it.

  4. 04

    Consider what leaves the exhaust

    In electronics and cleanroom work, exhaust air quality usually matters as much as pickup — absolute filtration keeps the fine fraction captured.

Where this line is used

Not listed? Browse the full industry directory or start from your material. New to dust hazards? Start with how dust explosions work or vacuum vs dust collector.

Frequently asked questions

Should I choose an electric or an air-operated vacuum?
It usually comes down to two things: your area classification and whether you have adequate compressed air at the point of use. An air-operated unit is driven by compressed air through a venturi, so there is no electric motor, no switch and no cord in the recovery unit at all — which removes the electrical ignition question from the drive entirely and suits long continuous running. Electric units suit facilities without sufficient plant air. Both are built with the same conductive, grounded and bonded recovery path, because the dust carries static regardless of what drives the machine. Air units are louder, which is worth planning for in occupied areas.
What is the difference between HEPA and ULPA filtration?
They are tested at different particle sizes and efficiencies. Standard HEPA is tested to a minimum of 99.97% efficiency at 0.3 micrometres; PrestiVac units are rated at 99.99% absolute, and factory H14 grades reach 99.995%. ULPA extends further, to 99.9995% at 0.12 micrometres. Which you need follows the requirement — the room classification, the exposure limit, or the sanitation standard — rather than a preference for the larger number. Ask what a filter is tested to rather than what it is called.
Do you supply dust collectors?
No. We manufacture industrial vacuums — explosion-proof, HEPA, air-operated, wet and dry, central systems and custom-built units. A dust collector is a different machine: high air volume at low suction, capturing dust at the source through fixed ducting. A vacuum is lower volume at high suction, removing what has already settled. Most dust programmes need both, and we would rather point you to a collection-system specialist for that half than sell you the wrong equipment.
Can one vacuum handle several different materials?
Sometimes, but it is worth checking rather than assuming. The constraints are the most demanding material in the mix, the classification of every area the unit will enter, and whether any of the materials should be kept separate. Reactive metal fines should not be combined with other debris or with coolant, and regulated toxic materials such as lead, cadmium and beryllium call for dedicated equipment that never leaves the regulated area. A unit that also cleans the loading dock has no business in a cleanroom.
Do you build custom systems?
Yes — custom-built systems are part of the range, and with more than 200 versions built over the years most requirements have a precedent. The useful thing to bring is constraints rather than a specification: the material, the area classification, the duty cycle, the footprint available, and how recovered material needs to leave the building. Those five determine what can be built, and asking early about the certification documents your compliance process will require means the build produces them.
All questions

Get a Quote

Tell us your material, your classification and how hard you will work it. Our technical team will recommend the PrestiVac model best suited to the job.

Get a Quote

Talk to the manufacturer

Get the right explosion proof vacuum for your application.

Tell us what you need to vacuum and where. Our technical team will recommend the PrestiVac model best suited to your material, your classification and how hard you will work it — and because we build every unit ourselves, we can modify it to fit.

  • Legally certified explosion proof
  • Solid stainless steel construction
  • Industry-best 3-year warranty
  • Designed & manufactured in the USA
  • 200+ vacuum versions