Skip to content
PrestiVac

EVX-10 EX HEPA

EVX SeriesElectric

Electric explosion-proof vacuums with HEPA filtration options.

Certification

UL 1203 · CSAClass II, Division 2, Groups F and G

Configuration

Explosion-proof constructionHEPA filtration
PrestiVac EVX-10 EX HEPA — EVX Series industrial vacuum

Product photography. Configuration may vary by specification.

Series
EVX Series
Power source
Electric
Tank capacity
10 gal
Airflow
142 CFM
Filtration
HEPA 99.995% @ 0.3 µm
Certification
UL 1203 — CSA
Construction
Stainless steel
Hazardous location scope
Cl. II, Div. 2, Gps. F and G

Technical

Specifications

What is confirmed for this model. Airflow, vacuum, motor and dimensions are model-specific and are supplied on the datasheet — we do not publish estimated figures.

Construction & configuration

Series
EVX Series
Power source
Electric
Configuration
EX · HEPA
Body
All Stainless steel construction makes it a solid unit that is easy to clean and sterilize
Cart
Stainless steel industrial cart assembly with ESD safe, conductive wheels
Static
Static dissipating ESD safe
Supplied with
Complete with static dissipating suction hose and accessories

Filtration

HEPA stage
HEPA Filtration with an efficiency of 99.995% @ 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822 and OSHA compliantFrom the factory brochure specification for this line.
Static control
Conductive ESD safe filters
Required media
Static-dissipating filters, per the certified configuration
Filter area
See datasheet

Electrical

Rating
EV1: 120V, 60Hz, 8A, 1020W. EV2: 120V, 60Hz, 16A, 2040W. Cord-connected, groundedFrom CSA Certificate 70122393
Connection
Cord-connected, grounded
Attachment plug
Installed by the end user; must be certified and rated for the locationCertificate note 2

Performance

Tank capacity
10 galFrom the model designation; suffixes denote tank size.
Airflow
142 CFMVaries by motor/venturi configuration, not by tank size. Exact figure on the datasheet.
Vacuum
68" H₂OVaries by motor/venturi configuration, not by tank size. Exact figure on the datasheet.
Air watts
321 AWVaries by motor/venturi configuration, not by tank size. Exact figure on the datasheet.
Weight & dimensions
See datasheet

Certification & compliance

Standard
UL 1203 (5th Edition)
Certifying body
CSA Group
Certificate
70122393
Scope
Cl. II, Div. 2, Gps. F and G
Use limitation
Commercial, indoor use only, in hazardous locations.
Attachment plug
The attachment plug is installed by the end user and must itself be certified and suitably rated for the hazardous location the vacuum is installed in. (Certificate note 2.)
Use limitation
Commercial, indoor use only, in hazardous locations. (Certificate.)
Grounding and bonding
Cord-connected and grounded. Grounded and bonded in accordance with the National Electrical Code, Article 250.
Hoses
Static-dissipating hose is required.
Filters
Static-dissipating filters are required.
Hoses and tools
Only PrestiVac-supplied hoses and tools maintain the certified configuration. Substituting third-party hoses or tools takes the unit outside the scope of the listing.

Full specifications, drawings and certification documents are issued per configuration. Tell us the application and we will send the set that applies to it.

Request documents

Compatibility

Which materials does this model's certified scope cover?

This table reports certification scope, not a safety clearance. Class II groups come from the certificate: Group E is conductive metal dust, F is carbonaceous, G is other non-conductive dust.

Class II group and certified-scope coverage by material for EVX-10 EX HEPA
MaterialClass II groupWithin scopeNote
MercuryGroup G YesGroup G is within this model's certified scope.
Milk PowderGroup G YesGroup G is within this model's certified scope.
Whey PowderGroup G YesGroup G is within this model's certified scope.
Egg PowderGroup G YesGroup G is within this model's certified scope.
Spice DustGroup G YesGroup G is within this model's certified scope.
Garlic PowderGroup G YesGroup G is within this model's certified scope.
Onion PowderGroup G YesGroup G is within this model's certified scope.
Cinnamon DustGroup G YesGroup G is within this model's certified scope.
Pepper DustGroup G YesGroup G is within this model's certified scope.
Paprika DustGroup G YesGroup G is within this model's certified scope.
Protein PowderGroup G YesGroup G is within this model's certified scope.
Soy ProteinGroup G YesGroup G is within this model's certified scope.

Scope is not suitability. Whether a specific material can be recovered safely also depends on its behaviour as your process generates it — established by testing — and on the area classification assigned by your own electrical or process engineer. Confirm with a PrestiVac application specialist before ordering for a hazardous application.

All 80 material guides · How the dust groups work

Compliance

Certification and what it covers

Read the scope rather than the phrase. A listing names specific classes, groups and a temperature code, and it means nothing outside them.

UL 1203 (5th Edition) — listed by CSA Group

Certificate 70122393 · Master Contract 268761 · issued 2018-07-18

  • Class II, Division 2, Groups F and G

Scope wording: “Dry Vacuum Cleaner, models EV1-1 EX HEPA (canister type), EV1-xx EX HEPA (Drum Type) and EV2-xx EX HEPA (Drum Type)”. Commercial, indoor use only, in hazardous locations.

Conditions of the configuration

  • Attachment plug: The attachment plug is installed by the end user and must itself be certified and suitably rated for the hazardous location the vacuum is installed in. (Certificate note 2.)
  • Use limitation: Commercial, indoor use only, in hazardous locations. (Certificate.)
  • Grounding and bonding: Cord-connected and grounded. Grounded and bonded in accordance with the National Electrical Code, Article 250.
  • Hoses: Static-dissipating hose is required.
  • Filters: Static-dissipating filters are required.
  • Hoses and tools: Only PrestiVac-supplied hoses and tools maintain the certified configuration. Substituting third-party hoses or tools takes the unit outside the scope of the listing.

Options

Configuration options on this model

What each designation on the model name means.

EX

Explosion-proof construction

Built for use in hazardous (classified) locations. Whether a specific unit is within the CSA listing is stated per model.

HEPA

HEPA filtration

Tested to EN 1822 (H14 by MPPS method). Retains the fine fraction rather than exhausting it back into the room.

Equipment

Hoses, tools and accessories

The listing covers the vacuum together with its hoses and tools. Substituting third-party accessories takes the unit outside the scope of its certification.

Range

Other models in the EVX Series

Same series, different configuration. Performance figures come from the datasheet for each model.

Configuration comparison within the EVX Series
ModelConfigurationCertified scope
EVX-10 EX HEPAViewingEX · HEPACl. II, Div. 2, Gps. F and G
EVX-5 EX RCT IS HEPAEX · HEPA · RCT · ISCl. II, Div. 2, Gps. F and GView
EVX-5 EX HEPAEX · HEPACl. II, Div. 2, Gps. F and GView
EVX-5-10 EX HEPAEX · HEPACl. II, Div. 2, Gps. F and GView
EVX-5-10 EX MR HEPAEX · HEPA · MRCl. II, Div. 2, Gps. F and GView

Estimate

What manual housekeeping costs you now

An arithmetic estimate from your own figures. It makes no claim about this model's performance.

Your assumption, not a PrestiVac performance claim.

Estimated annual labour

$11,700

260 hours of 520

An arithmetic estimate from the figures you entered. It is not a quotation, a payback guarantee, or a claim about any PrestiVac model’s performance.

Questions

Frequently asked

Which line is certified for metal dust?

The EX1 HEPA line. Its scope includes Class II, Groups E, F and G, and Group E is the conductive metal-dust group. The EV EX HEPA line is covered for Groups F and G only, so it does not carry Group E coverage — which matters directly in metalworking, aerospace, foundry and battery applications where the dust is frequently Group E. If you are specifying for aluminium, titanium, magnesium or other metal dust, ask us to confirm the line and scope against your area classification before ordering.

Which line can be used in a Division 1 area?

That depends on the line and on your area classification. The EX1 HEPA line is listed under explosion-proof and dust-ignition-proof enclosure standards. The EV EX HEPA line is listed as nonincendive equipment for Class II, Division 2 — it is not a Division 1 listing. Because Division 1 means the hazardous atmosphere is expected in normal operation, this distinction is not a technicality. Confirm the classification with your engineer and let us match the line to it.

Does your UL 1203 listing cover Class I Groups A, B and C?

No. Class I is Group D only — propane, methane and most common hydrocarbons and industrial solvents. Groups A, B and C cover acetylene, hydrogen and ethylene and are not within our listing. Note also that Class I coverage applies to the EX1 HEPA line only; the EV EX HEPA line has no Class I coverage at all, and is limited to Class II, Division 2, Groups F and G.

Can I use my own hoses and tools with a certified vacuum?

Not while keeping the unit in its certified configuration. The listing covers the vacuum together with PrestiVac-supplied hoses and tools, and static-dissipating hose and filters are required. Fitting a hose from general stores or a tool borrowed from another machine takes the unit outside the scope of its listing without anything visibly changing — which is why this tends to happen in service rather than at purchase.

How must a certified vacuum be grounded?

Grounded and bonded in accordance with the National Electrical Code, Article 250. Static-dissipating hose and filters are part of the required configuration. The practical point is that the path has to be continuous from the tool through the hose to the container — a grounded machine with a non-conductive hose attached leaves the charge generated in the hose with nowhere to go, and the machine will keep working normally without anyone noticing.

Should I choose an electric or an air-operated vacuum?

It usually comes down to two things: your area classification and whether you have adequate compressed air at the point of use. An air-operated unit is driven by compressed air through a venturi, so there is no electric motor, no switch and no cord in the recovery unit at all — which removes the electrical ignition question from the drive entirely and suits long continuous running. Electric units suit facilities without sufficient plant air. Both are built with the same conductive, grounded and bonded recovery path, because the dust carries static regardless of what drives the machine. Air units are louder, which is worth planning for in occupied areas.

What is the difference between HEPA and ULPA filtration?

They are tested at different particle sizes and efficiencies. Standard HEPA is tested to a minimum of 99.97% efficiency at 0.3 micrometres; PrestiVac units are rated at 99.99% absolute, and factory H14 grades reach 99.995%. ULPA extends further, to 99.9995% at 0.12 micrometres. Which you need follows the requirement — the room classification, the exposure limit, or the sanitation standard — rather than a preference for the larger number. Ask what a filter is tested to rather than what it is called.

Do you supply dust collectors?

No. We manufacture industrial vacuums — explosion-proof, HEPA, air-operated, wet and dry, central systems and custom-built units. A dust collector is a different machine: high air volume at low suction, capturing dust at the source through fixed ducting. A vacuum is lower volume at high suction, removing what has already settled. Most dust programmes need both, and we would rather point you to a collection-system specialist for that half than sell you the wrong equipment.

All questions

Not sure this is the right model?

Tell us the material, the area classification and how the unit will be used, and our technical team will confirm the model and configuration — or tell you if something else in the range fits better.

Talk to the manufacturer

Get the right explosion proof vacuum for your application.

Tell us what you need to vacuum and where. Our technical team will recommend the PrestiVac model best suited to your material, your classification and how hard you will work it — and because we build every unit ourselves, we can modify it to fit.

  • Legally certified explosion proof
  • Solid stainless steel construction
  • Industry-best 3-year warranty
  • Designed & manufactured in the USA
  • 200+ vacuum versions